Mitsubishi Heavy Industries 12.5kW 3 Phase Inverter Ducted System FDUA125AVSXWVH
Mitsubishi Heavy Industries 12.5kW 3 Phase Inverter Ducted System FDUA125AVSXWVH

Mitsubishi Heavy Industries

Mitsubishi Heavy Industries 12.5kW 3 Phase Inverter Ducted System FDUA125AVSXWVH

Sale price$4,788.00 Regular price$5,504.00
Save $716.00
No reviews
No reviews
MODEL: FDUA125VH / FDCA125VSX-W/3p
Quantity:
Found a better price?

Ducted & Split Systems Sizing Calculator

Use our split system or ducted sizing calculator below to determine the minimum size required for your room or house.

Note: For ducted systems only include the air conditioned spaces, exclude areas like garages, bathrooms or laundries.

 

Overview

Mitsubishi Heavy Industries FDUA125VH / FDCA125VSX-W 12.5kW High Static Ducted System | Three Phase

Indoor: FDUA125VH

Outdoor: FDCA125VSX-W - 3 Phase

Backlit Controller: RC-EXZ3A

Specifications

CAPACITY 12.5KW
Set FDUA125AVSXWVH
Indoor FDUA125VH
Outdoor FDCA125VSX-W
Power Source (Outdoor Unit) 3 Phase 380-415V 50Hz
 

 

 

 

 

 

 

 

 

 

*Operation Data

 

 

Nominal Capacity Range

Cooling T1  

 

 

 

kW

12.5 (5.0-14.0)
Heating H1 14.0 (4.0-18.0)
Heating H2 14.20
 

 

Power Consumption

Cooling T1 3.83
Heating H1 3.68
Max Power Consumption 7.66
 

 

Running Current

Cooling T1  

 

A

6.4
Heating H1 6.2
Inrush Current, Maximum Current 5, 18
EER Cooling T1 3.26
COP Heating H1 3.80
Sound Power Level (JS C9612) Outdoor  

 

 

dB(A)

70
Sound Pressure Level (JS C9612) Indoor P-Hi:46 Hi:44 Me:42 Lo:38
Outdoor 54
 

 

External Dimensions (HXWXD)

Indoor  

 

mm

398x1150x650
Outdoor 1300x970x370
 

 

Net Weight

Indoor  

 

Kg

52
Outdoor 99
Supply Air Connection  

 

mm

348×898
Return Air Connection 348×898
External Static Pressure (Max) Pa 200
Airflow Indoor (Cooling) l/s P-Hi:717 Hi:650

 

Me:600 Lo:500

Indoor (Heating)
 

 

Refrigerant (Type, Amount, Pre-charge Length)

Quantity kg (R32) 4.0
Pre Charged To Pipe

 

Length

m 30
 

 

 

 

Installation Data

 

 

Refrigerant Piping

Liquid Line  

 

mm

Ø9.52
Gas Line Ø15.88
Connection Method Flare connection
Maximum Pipe Length (One Way)  

 

m

100
Max vertical height diff. between O.U. and I.U. 30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2
Safety Pan (Optional) UA-SP2-E
Motion Sensor (Optional) LB-KIT2
Demand response (AS4755) Yes
Outdoor air temperature (upper, lower limits) Cooling  

 

oC

-15 to 50
Heating -20 to 20

NEED INSTALLATION QUOTE?

Fast Aus Wide Delivery

Most deliveries dispatched locally