Mitsubishi Heavy Industries 4kW Multi Head Outdoor Unit Only SCM40ZS-W

Mitsubishi Heavy Industries

Mitsubishi Heavy Industries 4kW Multi Head Outdoor Unit Only SCM40ZS-W

Sale price$1,441.00
No reviews
No reviews
MODEL: SCM40ZS-W
Quantity:
Found a better price?

Ducted & Split Systems Sizing Calculator

Use our split system or ducted sizing calculator below to determine the minimum size required for your room or house.

Note: For ducted systems only include the air conditioned spaces, exclude areas like garages, bathrooms or laundries.

 

Overview

Mitsubishi Heavy Industries SCM40ZS-W 4kW Multi Split System Outdoor Unit Only

Serves 2 indoor units | R32

Maximum capacity of indoor units allowed: 6kW


Specifications

Outdoor SCM40ZS-W
Power source (Outdoor) 1 Phase 240V 50Hz
 

 

 

 

 

 

 

 

 

*Operation data

 

 

Nominal Capacity (Range)

Cooling T1  

 

 

kW

4.0 (1.5~5.9)
Heating H1 4.5 (1.0~6.3)
 

 

Power consumption

Cooling T1 0.80
Heating H1 0.83
 

 

Running current

Cooling T1  

 

A

3.4
Heating H1 3.5
Inrush current, maximum current 3.7, 14
EER Cooling T1 5.00
COP Heating H1 5.42
 

 

Sound power level (JIS C9612)

Cooling T1  

 

 

 

dB(A)

62
Heating H1 64
 

 

Sound pressure level (JIS C9612)

Cooling T1 49
Heating H1 51
 

 

Silent mode

Cooling T1 44
Heating H1 46
External dimensions (HxWxD) mm 595×780(+90)x290
Net weight  

 

kg

40
 

 

Refrigerant (R32)

Quantity 1.4
Pre charged to pipe length m 20
 

 

 

 

Installation data

 

 

Refrigerant piping

Liquid line  

 

mm

Ø6.35 x 2
Gas line Ø9.52 x 2
Connection method Flare connection
Maximum pipe length to one indoor unit  

 

m

25
Total pipe length to all indoor units 30
Max vertical height diff. between O.U. and I.U. 15 ( O.U. above I.U.) / 15 ( O.U. below I.U. )
 

 

 

 

 

Indoor Unit Combination

SRK-ZSA-W  

 

 

 

 

kW

2.0, 2.5, 3.5
SRK-ZSXA-W 2.0, 2.5, 3.5
SRK-ZRA-W
SRF-ZS(X)-W 2.5, 3.5
SRR-ZS-W 2.5, 3.5
FDTC-VH 2.5, 3.5
FDUM-VH
Indoor Unit Connection 2 Units
Indoor Connection Capacity kW 4.0 to 6.0
 

 

Outdoor air temperature (upper, lower limits)

Cooling °C -15 to 46
Heating -15 to 24
* Operation data are are conducted in accordance with AS/NZS 3823 standard. For testing conditions please refer to Page14.

Fast Aus Wide Delivery

Most deliveries dispatched locally